Single or double amplifier for connection of maximum 4 strain gauge bridges,
with display, easy to adjust
- Input: up to 4 strain gauge full bridges
- Input sensitivity: 0,1...5 mV/V
- Analog output: 4...20 mA / 0...10 V
- Voltage supply: 24 VDC +/-30%
- Resolution: 12 / 14 / 15 / 16 bit
- Combiened error: 0,2% of end scale value
- Optionally: limit value switch / interface / vibration protection
- Degree of protection: IP65
- Adjustment: via RS232 interface
|
|
Double amplifier for connection of 2 strain gauge bridges,
with display, programmable, for service
- Input: 2 strain gauge full bridges
- Input sensitivity: 0,1...5 mV/V
- Analog output: 4...20 mA / 0...10 V
- Voltage supply: accumulator
- Resolution: 12 / 14 / 15 / 16 bit
- Combiened error: 0,2% of end scale value
- Degree of protection: IP54
- Adjustment: via RS232 interface
or programming keys
|
|
| DIGITAL MEASURING AMPLIFIER FOR STRAIN GAUGE |
SU - DX |
ID: DL |
Measuring amplifier in top hat rail enclosure with analogue outputs
and serial interface. Suitable for nearly all ranges of laod/force measuring
- Input sensivity 01 to 5 mV/V
- Programmable via RS232 interface
- Analog output 4...20 mA and 0...10 V
- Supply voltage 24 VDC +/- 30%
- Combiend error 0,2% FS
- Resolution 12 / 14 / 15 / 16 bit
- Enclosure plastics
- Degree of protection IP 67
|
|
For connection of maximum 6 strain gauge full bridges
with 4 or 6 wires
- Input: 6 strain gauge full bridges
- Output: 1 strain gauge summing-up signal
- Sensors: 4- or 6-wires
- Bridge supply: out of amplifier or internally
- Supply: 12...30 VDC VDC (optionally)
- Cascade circuit possible
- Connection: screwed pin and socket, lockable
- Cable entries: 7 pcs M16x1,5
|
|
in top hat rail case for all weighing-technical applications
- Input sensitivity (0,1 mV/V up to 4 mV/V)
selectable by DIP-switches
- Connection of max. 4 resistance strain
gauge sensors (full bridge, 350 ohms)
- Change over analog output
0 (4)...+/- 20 mA or 0 (2)...+/-10 V
- Sensor supply voltage internally
continiously adjustable (4...14 V)
- Optionally 2 adjustable limit value
switches (potential free change over contacts)
- Accuracy +/-0,1% of end of scale value
- Supply voltage 115/230 VAC
or 24 VAC/DC
|
|
in field case for all weighing-technical applications
- Input sensitivity (0,1 mV/V up to 4 mV/V)
selectable by DIP-switches
- Connection of max. 4 resistance strain
gauge sensors (full bridge, 350 ohms)
- Change over analog output
0 (4)...+/- 20 mA or 0 (2)...+/-10 V
- Sensor supply voltage internally
continiously adjustable (4...14 V)
- Accuracy +/-0,1% of end of scale value
- Supply voltage 115/230 VAC
or 24 VAC/DC, galvanic separation
|
|
| DIGITAL MEASURING AMPLIFIER FOR STRAIN GAUGE |
ADLM - LC |
ID: LA |
in tube shaped case for interface adaption
between sensor and control
- Input sensivity 01 to 5 mV/V
- Programmable via RS232 interface
- Analog output 4...20 mA and 0...10 V
- Supply voltage 24 VDC +/- 30%
- Combiend error 0,2% FS
- Resolution 12 / 14 / 15 / 16 bit
- Enclosure stainless steel
- Degree of protection IP 67
|
|
in robust field case for all weighing-technical applications
- 4 inputs resistance strain gauge,
full bridges
- Addition of single measure values
- 1 output for connection to every measuring
amplifier with input for resistance
strain gauge bridges
- Cascading of several summing amplifiers
is possible
- External power supply for the bridges
can be connected on demand
|
|